{"id":5730,"date":"2025-09-20T18:35:27","date_gmt":"2025-09-20T16:35:27","guid":{"rendered":"https:\/\/ascomedic.dz\/?post_type=product&#038;p=5730"},"modified":"2026-01-27T19:23:19","modified_gmt":"2026-01-27T18:23:19","slug":"analyseur-dhematologie-h60-edan","status":"publish","type":"product","link":"https:\/\/ascomedic.dz\/en\/product\/analyseur-dhematologie-h60-edan\/","title":{"rendered":"H60 \u2013 EDAN"},"content":{"rendered":"<h2 data-start=\"868\" data-end=\"890\"><strong data-start=\"871\" data-end=\"890\">Fiche Technique<\/strong><\/h2>\n<h3 data-start=\"892\" data-end=\"928\"><strong data-start=\"896\" data-end=\"928\">Caract\u00e9ristiques g\u00e9n\u00e9rales :<\/strong><\/h3>\n<ul data-start=\"929\" data-end=\"1298\">\n<li data-start=\"929\" data-end=\"965\">\n<p data-start=\"931\" data-end=\"965\"><strong data-start=\"931\" data-end=\"950\">Marque \/ Mod\u00e8le<\/strong> : EDAN \u2013 H60<\/p>\n<\/li>\n<li data-start=\"966\" data-end=\"1032\">\n<p data-start=\"968\" data-end=\"1032\"><strong data-start=\"968\" data-end=\"987\">Type d\u2019automate<\/strong> : Analyseur d\u2019h\u00e9matologie automatis\u00e9 (IVD)<\/p>\n<\/li>\n<li data-start=\"1033\" data-end=\"1298\">\n<p data-start=\"1035\" data-end=\"1061\"><strong data-start=\"1035\" data-end=\"1057\">M\u00e9thodes de mesure<\/strong> :<\/p>\n<ul data-start=\"1064\" data-end=\"1298\">\n<li data-start=\"1064\" data-end=\"1134\">\n<p data-start=\"1066\" data-end=\"1134\">Imp\u00e9dance \u00e9lectrique pour les <strong data-start=\"1096\" data-end=\"1108\">GR (RBC)<\/strong> et <strong data-start=\"1112\" data-end=\"1132\">plaquettes (PLT)<\/strong><\/p>\n<\/li>\n<li data-start=\"1137\" data-end=\"1215\">\n<p data-start=\"1139\" data-end=\"1215\">Cytom\u00e9trie optique par laser et fluorescence pour les <strong data-start=\"1193\" data-end=\"1213\">leucocytes (WBC)<\/strong><\/p>\n<\/li>\n<li data-start=\"1218\" data-end=\"1298\">\n<p data-start=\"1220\" data-end=\"1298\">Colorim\u00e9trie photom\u00e9trique au cyanm\u00e9th\u00e9moglobine pour l\u2019<strong data-start=\"1276\" data-end=\"1296\">h\u00e9moglobine (Hb)<\/strong><\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<hr data-start=\"1300\" data-end=\"1303\" \/>\n<h3 data-start=\"1305\" data-end=\"1334\"><strong data-start=\"1309\" data-end=\"1334\">Param\u00e8tres analys\u00e9s :<\/strong><\/h3>\n<ul data-start=\"1335\" data-end=\"1724\">\n<li data-start=\"1335\" data-end=\"1387\">\n<p data-start=\"1337\" data-end=\"1387\"><strong data-start=\"1337\" data-end=\"1359\">Num\u00e9ration de base<\/strong> : WBC, RBC, HGB, HCT, PLT<\/p>\n<\/li>\n<li data-start=\"1388\" data-end=\"1452\">\n<p data-start=\"1390\" data-end=\"1452\"><strong data-start=\"1390\" data-end=\"1417\">Indices \u00e9rythrocytaires<\/strong> : MCV, MCH, MCHC, RDW-SD, RDW-CV<\/p>\n<\/li>\n<li data-start=\"1453\" data-end=\"1498\">\n<p data-start=\"1455\" data-end=\"1498\"><strong data-start=\"1455\" data-end=\"1480\">Indices plaquettaires<\/strong> : MPV, PDW, PCT<\/p>\n<\/li>\n<li data-start=\"1499\" data-end=\"1567\">\n<p data-start=\"1501\" data-end=\"1567\"><strong data-start=\"1501\" data-end=\"1530\">Diff\u00e9rentiel leucocytaire<\/strong> : 5-part (NEU, LYM, MON, EOS, BAS)<\/p>\n<\/li>\n<li data-start=\"1568\" data-end=\"1677\">\n<p data-start=\"1570\" data-end=\"1677\"><strong data-start=\"1570\" data-end=\"1603\">Indices leucocytaires avanc\u00e9s<\/strong> : Immature Granulocytes (IG), NRBC (si disponibles selon configuration)<\/p>\n<\/li>\n<li data-start=\"1678\" data-end=\"1724\">\n<p data-start=\"1680\" data-end=\"1724\"><strong data-start=\"1680\" data-end=\"1710\">Nombre total de param\u00e8tres<\/strong> : ~ 29 \u2013 32<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"1726\" data-end=\"1729\" \/>\n<h3 data-start=\"1731\" data-end=\"1752\"><strong data-start=\"1735\" data-end=\"1752\">Performance :<\/strong><\/h3>\n<ul data-start=\"1753\" data-end=\"2036\">\n<li data-start=\"1753\" data-end=\"1808\">\n<p data-start=\"1755\" data-end=\"1808\"><strong data-start=\"1755\" data-end=\"1776\">Vitesse d\u2019analyse<\/strong> : Jusqu\u2019\u00e0 60 \u2013 80 tests\/heure<\/p>\n<\/li>\n<li data-start=\"1809\" data-end=\"1920\">\n<p data-start=\"1811\" data-end=\"1846\"><strong data-start=\"1811\" data-end=\"1842\">Volume d\u2019\u00e9chantillon requis<\/strong> :<\/p>\n<ul data-start=\"1849\" data-end=\"1920\">\n<li data-start=\"1849\" data-end=\"1871\">\n<p data-start=\"1851\" data-end=\"1871\">Mode ferm\u00e9 : 20 \u00b5L<\/p>\n<\/li>\n<li data-start=\"1874\" data-end=\"1920\">\n<p data-start=\"1876\" data-end=\"1920\">Mode ouvert (capillaire \/ urgence) : 50 \u00b5L<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"1921\" data-end=\"1975\">\n<p data-start=\"1923\" data-end=\"1975\"><strong data-start=\"1923\" data-end=\"1951\">Temps de rendu d\u2019un test<\/strong> : Environ 60 secondes<\/p>\n<\/li>\n<li data-start=\"1976\" data-end=\"2036\">\n<p data-start=\"1978\" data-end=\"2036\"><strong data-start=\"1978\" data-end=\"1991\">Pr\u00e9cision<\/strong> : Conforme aux normes internationales CLSI<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"2038\" data-end=\"2041\" \/>\n<h3 data-start=\"2043\" data-end=\"2074\"><strong data-start=\"2047\" data-end=\"2074\">Interface et Logiciel :<\/strong><\/h3>\n<ul data-start=\"2075\" data-end=\"2476\">\n<li data-start=\"2075\" data-end=\"2138\">\n<p data-start=\"2077\" data-end=\"2138\"><strong data-start=\"2077\" data-end=\"2086\">\u00c9cran<\/strong> : \u00c9cran tactile couleur haute r\u00e9solution (10,4\u2019\u2019)<\/p>\n<\/li>\n<li data-start=\"2139\" data-end=\"2255\">\n<p data-start=\"2141\" data-end=\"2255\"><strong data-start=\"2141\" data-end=\"2161\">Logiciel int\u00e9gr\u00e9<\/strong> : Interface intuitive avec affichage des <strong data-start=\"2203\" data-end=\"2219\">scattergrams<\/strong> et <strong data-start=\"2223\" data-end=\"2239\">histogrammes<\/strong> en temps r\u00e9el<\/p>\n<\/li>\n<li data-start=\"2256\" data-end=\"2330\">\n<p data-start=\"2258\" data-end=\"2330\"><strong data-start=\"2258\" data-end=\"2281\">Gestion des donn\u00e9es<\/strong> : Archivage jusqu\u2019\u00e0 100 000 r\u00e9sultats patients<\/p>\n<\/li>\n<li data-start=\"2331\" data-end=\"2385\">\n<p data-start=\"2333\" data-end=\"2385\"><strong data-start=\"2333\" data-end=\"2349\">Connectivit\u00e9<\/strong> : LIS \/ HL7, USB, Ethernet, RS232<\/p>\n<\/li>\n<li data-start=\"2386\" data-end=\"2476\">\n<p data-start=\"2388\" data-end=\"2476\"><strong data-start=\"2388\" data-end=\"2410\">Fonctions avanc\u00e9es<\/strong> : Contr\u00f4le qualit\u00e9 (L-J QC), autocalibration, suivi statistique<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"2478\" data-end=\"2481\" \/>\n<h3 data-start=\"2483\" data-end=\"2517\"><strong data-start=\"2487\" data-end=\"2517\">Conditions d\u2019utilisation :<\/strong><\/h3>\n<ul data-start=\"2518\" data-end=\"2755\">\n<li data-start=\"2518\" data-end=\"2563\">\n<p data-start=\"2520\" data-end=\"2563\"><strong data-start=\"2520\" data-end=\"2536\">Alimentation<\/strong> : AC 100\u2013240 V, 50\/60 Hz<\/p>\n<\/li>\n<li data-start=\"2564\" data-end=\"2617\">\n<p data-start=\"2566\" data-end=\"2617\"><strong data-start=\"2566\" data-end=\"2599\">Temp\u00e9rature de fonctionnement<\/strong> : 15 \u00b0C \u2013 30 \u00b0C<\/p>\n<\/li>\n<li data-start=\"2618\" data-end=\"2670\">\n<p data-start=\"2620\" data-end=\"2670\"><strong data-start=\"2620\" data-end=\"2641\">Humidit\u00e9 relative<\/strong> : \u2264 85 % sans condensation<\/p>\n<\/li>\n<li data-start=\"2671\" data-end=\"2716\">\n<p data-start=\"2673\" data-end=\"2716\"><strong data-start=\"2673\" data-end=\"2687\">Dimensions<\/strong> : 430 mm \u00d7 370 mm \u00d7 510 mm<\/p>\n<\/li>\n<li data-start=\"2717\" data-end=\"2755\">\n<p data-start=\"2719\" data-end=\"2755\"><strong data-start=\"2719\" data-end=\"2732\">Poids net<\/strong> : Environ 26 \u2013 28 kg<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"2757\" data-end=\"2760\" \/>\n<h3 data-start=\"2762\" data-end=\"2793\"><strong data-start=\"2766\" data-end=\"2793\">Conformit\u00e9 &amp; S\u00e9curit\u00e9 :<\/strong><\/h3>\n<ul data-start=\"2794\" data-end=\"3038\">\n<li data-start=\"2794\" data-end=\"2859\">\n<p data-start=\"2796\" data-end=\"2859\">Conforme aux normes <strong data-start=\"2816\" data-end=\"2826\">CE-IVD<\/strong> et certification <strong data-start=\"2844\" data-end=\"2857\">ISO 13485<\/strong><\/p>\n<\/li>\n<li data-start=\"2860\" data-end=\"2911\">\n<p data-start=\"2862\" data-end=\"2911\">Syst\u00e8me de contr\u00f4le qualit\u00e9 int\u00e9gr\u00e9 (3 niveaux)<\/p>\n<\/li>\n<li data-start=\"2912\" data-end=\"2957\">\n<p data-start=\"2914\" data-end=\"2957\">Autodiagnostic et maintenance automatis\u00e9e<\/p>\n<\/li>\n<li data-start=\"2958\" data-end=\"3038\">\n<p data-start=\"2960\" data-end=\"3038\">Alerte en cas de blocage, aspiration insuffisante ou anomalies d\u2019\u00e9chantillon<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"3040\" data-end=\"3043\" \/>\n<h2 data-start=\"3045\" data-end=\"3066\"><strong data-start=\"3048\" data-end=\"3066\">Points Forts :<\/strong><\/h2>\n<p data-start=\"3067\" data-end=\"3430\">\u2714 Technologie hybride (imp\u00e9dance + cytom\u00e9trie optique + fluorescence)<br data-start=\"3136\" data-end=\"3139\" \/>\u2714 D\u00e9tection fiable avec diff\u00e9rentiel leucocytaire <strong data-start=\"3189\" data-end=\"3199\">5-part<\/strong><br data-start=\"3199\" data-end=\"3202\" \/>\u2714 Haut d\u00e9bit (jusqu\u2019\u00e0 80 \u00e9chantillons\/heure)<br data-start=\"3246\" data-end=\"3249\" \/>\u2714 Faible volume d\u2019\u00e9chantillon requis, id\u00e9al pour p\u00e9diatrie et urgence<br data-start=\"3318\" data-end=\"3321\" \/>\u2714 Interface tactile intuitive + connectivit\u00e9 LIS\/HL7<br data-start=\"3373\" data-end=\"3376\" \/>\u2714 Archivage longue dur\u00e9e et contr\u00f4le qualit\u00e9 int\u00e9gr\u00e9<\/p>","protected":false},"excerpt":{"rendered":"<h1 data-start=\"132\" data-end=\"174\"><strong data-start=\"134\" data-end=\"172\">Analyseur d\u2019H\u00e9matologie H60 \u2013 EDAN<\/strong><\/h1>\n<h3 data-start=\"175\" data-end=\"263\">Automate de Diagnostic M\u00e9dical IVD \u2013 Num\u00e9ration Globulaire et Formule Leucocytaire<\/h3>\n<hr data-start=\"265\" data-end=\"268\" \/>\n<h2 data-start=\"270\" data-end=\"300\"><strong data-start=\"273\" data-end=\"298\">Pr\u00e9sentation G\u00e9n\u00e9rale<\/strong><\/h2>\n<p data-start=\"301\" data-end=\"861\">L\u2019<strong data-start=\"303\" data-end=\"334\">analyseur d\u2019h\u00e9matologie H60<\/strong> de la marque <strong data-start=\"348\" data-end=\"356\">EDAN<\/strong> est un automate <strong data-start=\"373\" data-end=\"402\">In Vitro Diagnostic (IVD)<\/strong> de derni\u00e8re g\u00e9n\u00e9ration, con\u00e7u pour fournir une num\u00e9ration globulaire compl\u00e8te et une diff\u00e9renciation leucocytaire fiable.<\/p>\n<p data-start=\"301\" data-end=\"861\">Il int\u00e8gre des technologies avanc\u00e9es de <strong data-start=\"567\" data-end=\"604\">cytom\u00e9trie optique \u00e0 fluorescence<\/strong>, de <strong data-start=\"609\" data-end=\"640\">dispersion de lumi\u00e8re laser<\/strong> et de <strong data-start=\"647\" data-end=\"681\">m\u00e9thode d\u2019imp\u00e9dance \u00e9lectrique<\/strong> pour garantir des r\u00e9sultats de haute pr\u00e9cision.<\/p>\n<p data-start=\"301\" data-end=\"861\">Compact, rapide et convivial, il r\u00e9pond parfaitement aux besoins des laboratoires cliniques, h\u00f4pitaux et centres de diagnostic.<\/p>\n<p data-start=\"301\" data-end=\"861\"><strong>T\u00e9l\u00e9chargement de la fiche technique :<\/strong> <a href=\"https:\/\/mega.nz\/file\/rh4yDTzK#pymkEjqVRyOi6vyw253dUZetEYa-9Irxgd-wiCI36wM\"><strong>Cliquez ici<\/strong><\/a><\/p>","protected":false},"featured_media":5732,"comment_status":"open","ping_status":"closed","template":"","meta":{"content-type":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[213],"product_tag":[],"class_list":{"0":"post-5730","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hematologie","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>H60 \u2013 EDAN -<\/title>\n<meta name=\"description\" content=\"Analyseur d\u2019h\u00e9matologie EDAN H60. Automate IVD haut d\u00e9bit, 5-part diff\u00e9rentiel avec IG et NRBC, r\u00e9sultats fiables et connectivit\u00e9 HL7.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ascomedic.dz\/en\/product\/analyseur-dhematologie-h60-edan\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"H60 \u2013 EDAN -\" \/>\n<meta property=\"og:description\" content=\"Analyseur d\u2019h\u00e9matologie EDAN H60. Automate IVD haut d\u00e9bit, 5-part diff\u00e9rentiel avec IG et NRBC, r\u00e9sultats fiables et connectivit\u00e9 HL7.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ascomedic.dz\/en\/product\/analyseur-dhematologie-h60-edan\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-27T18:23:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ascomedic.dz\/wp-content\/uploads\/2025\/09\/Products-2-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"2560\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/\",\"url\":\"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/\",\"name\":\"H60 \u2013 EDAN -\",\"isPartOf\":{\"@id\":\"https:\/\/ascomedic.dz\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ascomedic.dz\/wp-content\/uploads\/2025\/09\/Products-2-scaled.jpg\",\"datePublished\":\"2025-09-20T16:35:27+00:00\",\"dateModified\":\"2026-01-27T18:23:19+00:00\",\"description\":\"Analyseur d\u2019h\u00e9matologie EDAN H60. Automate IVD haut d\u00e9bit, 5-part diff\u00e9rentiel avec IG et NRBC, r\u00e9sultats fiables et connectivit\u00e9 HL7.\",\"breadcrumb\":{\"@id\":\"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/#primaryimage\",\"url\":\"https:\/\/ascomedic.dz\/wp-content\/uploads\/2025\/09\/Products-2-scaled.jpg\",\"contentUrl\":\"https:\/\/ascomedic.dz\/wp-content\/uploads\/2025\/09\/Products-2-scaled.jpg\",\"width\":2560,\"height\":2560},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/ascomedic.dz\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Boutique\",\"item\":\"https:\/\/ascomedic.dz\/boutique\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"H60 \u2013 EDAN\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ascomedic.dz\/#website\",\"url\":\"https:\/\/ascomedic.dz\/\",\"name\":\"\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ascomedic.dz\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"H60 \u2013 EDAN -","description":"Analyseur d\u2019h\u00e9matologie EDAN H60. Automate IVD haut d\u00e9bit, 5-part diff\u00e9rentiel avec IG et NRBC, r\u00e9sultats fiables et connectivit\u00e9 HL7.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ascomedic.dz\/en\/product\/analyseur-dhematologie-h60-edan\/","og_locale":"en_GB","og_type":"article","og_title":"H60 \u2013 EDAN -","og_description":"Analyseur d\u2019h\u00e9matologie EDAN H60. Automate IVD haut d\u00e9bit, 5-part diff\u00e9rentiel avec IG et NRBC, r\u00e9sultats fiables et connectivit\u00e9 HL7.","og_url":"https:\/\/ascomedic.dz\/en\/product\/analyseur-dhematologie-h60-edan\/","article_modified_time":"2026-01-27T18:23:19+00:00","og_image":[{"width":2560,"height":2560,"url":"https:\/\/ascomedic.dz\/wp-content\/uploads\/2025\/09\/Products-2-scaled.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/","url":"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/","name":"H60 \u2013 EDAN -","isPartOf":{"@id":"https:\/\/ascomedic.dz\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/#primaryimage"},"image":{"@id":"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/#primaryimage"},"thumbnailUrl":"https:\/\/ascomedic.dz\/wp-content\/uploads\/2025\/09\/Products-2-scaled.jpg","datePublished":"2025-09-20T16:35:27+00:00","dateModified":"2026-01-27T18:23:19+00:00","description":"Analyseur d\u2019h\u00e9matologie EDAN H60. Automate IVD haut d\u00e9bit, 5-part diff\u00e9rentiel avec IG et NRBC, r\u00e9sultats fiables et connectivit\u00e9 HL7.","breadcrumb":{"@id":"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/#primaryimage","url":"https:\/\/ascomedic.dz\/wp-content\/uploads\/2025\/09\/Products-2-scaled.jpg","contentUrl":"https:\/\/ascomedic.dz\/wp-content\/uploads\/2025\/09\/Products-2-scaled.jpg","width":2560,"height":2560},{"@type":"BreadcrumbList","@id":"https:\/\/ascomedic.dz\/produit\/analyseur-dhematologie-h60-edan\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/ascomedic.dz\/"},{"@type":"ListItem","position":2,"name":"Boutique","item":"https:\/\/ascomedic.dz\/boutique\/"},{"@type":"ListItem","position":3,"name":"H60 \u2013 EDAN"}]},{"@type":"WebSite","@id":"https:\/\/ascomedic.dz\/#website","url":"https:\/\/ascomedic.dz\/","name":"","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ascomedic.dz\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"}]}},"_links":{"self":[{"href":"https:\/\/ascomedic.dz\/en\/wp-json\/wp\/v2\/product\/5730","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ascomedic.dz\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ascomedic.dz\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ascomedic.dz\/en\/wp-json\/wp\/v2\/comments?post=5730"}],"version-history":[{"count":2,"href":"https:\/\/ascomedic.dz\/en\/wp-json\/wp\/v2\/product\/5730\/revisions"}],"predecessor-version":[{"id":5847,"href":"https:\/\/ascomedic.dz\/en\/wp-json\/wp\/v2\/product\/5730\/revisions\/5847"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ascomedic.dz\/en\/wp-json\/wp\/v2\/media\/5732"}],"wp:attachment":[{"href":"https:\/\/ascomedic.dz\/en\/wp-json\/wp\/v2\/media?parent=5730"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ascomedic.dz\/en\/wp-json\/wp\/v2\/product_brand?post=5730"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ascomedic.dz\/en\/wp-json\/wp\/v2\/product_cat?post=5730"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ascomedic.dz\/en\/wp-json\/wp\/v2\/product_tag?post=5730"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}